Specific To PALC M3-3V
Parameter Specification
Communication RS-232 9600 Baud, 1 stop bit, no parity, no handshaking.
ASCII text.
Internal Sample Timebase Rates: 1Hz, 2Hz, 5Hz, 10Hz
Period: 00:01 to 10:59 min:sec
Supply Voltage 2V to 4.5V. Supplied by 2 size AA cells.

Battery Life
(alkaline cells, outputs unloaded)

30 days continuous service while converting and sending by RS-232 to host computer.
Approximately 3 years in sleep mode.
Current Drain
(digital inputs terminated, outputs unloaded)
3.0 mA typical while active and driving an active RS-232 serial port.
1.5 mA typical while active but not driving a port (used as a controller for example).
90 uA typical in sleep mode.
Low Battery Indication [LOWBAT] text is prepended to output data string if battery voltage is less than 2.1V.
 